Everyone

Heat Pump Efficiency Ratings Explained: SEER2, HSPF2, COP and EER2

What SEER2, HSPF2, EER2 and COP mean, how they differ from older ratings, and how to use them to compare heat pumps.

Spec sheets for heat pumps are full of acronyms. These are the ones that matter most when comparing equipment.

SEER2: seasonal cooling efficiency

Seasonal Energy Efficiency Ratio 2 measures cooling output over a typical cooling season divided by electricity used. Higher is better. SEER2 replaced the older SEER rating in the U.S. in 2023, under a test procedure that better reflects real ductwork. SEER2 numbers are lower than SEER numbers for the same equipment, so don't compare a SEER2 figure against a SEER figure.

HSPF2: seasonal heating efficiency

Heating Seasonal Performance Factor 2 measures heating output over a typical heating season divided by electricity used. Higher is better. Like SEER2, it replaced an older rating (HSPF) in 2023, and the new numbers are lower than the old ones for the same unit. If you live somewhere cold, HSPF2 and low-temperature capacity matter more than SEER2.

EER2: peak cooling efficiency

Energy Efficiency Ratio 2 measures cooling efficiency at a single hot condition rather than across a season. It's a useful indicator for very hot climates, where systems spend a lot of time at peak load.

COP: coefficient of performance

COP is the instantaneous ratio of heat delivered to electricity used under specific conditions. A COP of 3 at 47°F means three units of heat per unit of electricity at that outdoor temperature. Manufacturers often publish COP at several temperatures, and COP at 5°F is a good indicator of cold-weather efficiency. Commercial equipment and geothermal systems are often rated by COP.

ENERGY STAR and other labels

  • ENERGY STAR certifies equipment that meets efficiency criteria above the federal minimum, including a separate cold-climate designation.
  • AHRI certificates confirm the rated performance of a specific matched combination of outdoor and indoor units. Ask your installer for the AHRI reference number of the exact system they quote, since many rebates require it.
  • NEEP's cold-climate list publishes detailed low-temperature performance data.

Using ratings wisely

Ratings compare equipment under standard conditions. Real-world results depend just as much on correct sizing, good installation, duct condition and controls. A well-installed, right-sized system with average ratings will often outperform a top-rated system that is oversized or poorly installed. Read how to choose an installer.

This guide is general information, not professional advice. Every building is different; get a load calculation and written quotes from licensed contractors before deciding. Spotted an error? Let us know.

Get the heat pump briefing

New guides, incentive changes and buying advice, sent occasionally. No spam, unsubscribe anytime.